Export limit exceeded: 430208 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 56021 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (56021 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-51979 2026-04-15 7.2 High
An authenticated attacker may trigger a stack based buffer overflow by performing a malformed request to either the HTTP service (TCP port 80), the HTTPS service (TCP port 443), or the IPP service (TCP port 631). The malformed request will contain an empty Origin header value and a malformed Referer header value. The Referer header value will trigger a stack based buffer overflow when the host value in the Referer header is processed and is greater than 64 bytes in length.
CVE-2025-55164 1 Content-security-policy-parser Project 1 Content-security-policy-parser 2026-04-15 N/A
content-security-policy-parser parses content security policy directives. A prototype pollution vulnerability exists in versions 0.5.0 and earlier, wherein if a policy name is called __proto__, one can override the Object prototype. This issue has been patched in version 0.6.0. A workaround involves disabling prototype method in NodeJS, neutralizing all possible prototype pollution attacks. Provide either --disable-proto=delete (recommended) or --disable-proto=throw as an argument to node to enable this feature.
CVE-2025-6093 2026-04-15 5.5 Medium
A vulnerability classified as critical was found in uYanki board-stm32f103rc-berial up to 84daed541609cb7b46854cc6672a275d1007e295. This vulnerability affects the function heartrate1_i2c_hal_write of the file 7.Example/hal/i2c/max30100/Manual/demo2/2/heartrate1_hal.c. The manipulation of the argument num leads to stack-based buffer overflow. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available.
CVE-2025-6091 2026-04-15 8.8 High
A vulnerability was found in H3C GR-3000AX V100R007L50. It has been classified as critical. Affected is the function UpdateWanParamsMulti/UpdateIpv6Params of the file /routing/goform/aspForm. The manipulation of the argument param leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor confirms the existence of this issue. Because they assess the risk as low, they do not have immediate plans for remediation.
CVE-2025-27708 1 Intel 1 Converged Security Management Engine Firmware 2026-04-15 4.1 Medium
Out-of-bounds read in the firmware for some Intel(R) Converged Security and Management Engine (CSME) Firmware (FW) within Ring 0: Kernel may allow an information disclosure. System software adversary with a privileged user combined with a low complexity attack may enable data exposure. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (none) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-6090 1 H3c 1 Gr-5400ax 2026-04-15 8.8 High
A vulnerability was found in H3C GR-5400AX V100R009L50 and classified as critical. This issue affects the function UpdateWanparamsMulti/UpdateIpv6params of the file /routing/goform/aspForm. The manipulation of the argument param leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor confirms the existence of this issue. Because they assess the risk as low, they do not have immediate plans for remediation.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2025-9041 1 Rockwellautomation 1 Flex 5000 Io 2026-04-15 N/A
A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle.
CVE-2024-51982 2026-04-15 7.5 High
An unauthenticated attacker who can connect to TCP port 9100 can issue a Printer Job Language (PJL) command that will crash the target device. The device will reboot, after which the attacker can reissue the command to repeatedly crash the device. A malformed PJL variable FORMLINES is set to a non number value causing the target to crash.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-0012 1 Amd 2 Epyc 9005 Series Processors, Epyc Embedded 9005 Series Processors 2026-04-15 N/A
Improper handling of overlap between the segmented reverse map table (RMP) and system management mode (SMM) memory could allow a privileged attacker corrupt or partially infer SMM memory resulting in loss of integrity or confidentiality.
CVE-2017-20205 1 Valvesoftware 2 Source, Source Sdk 2026-04-15 N/A
Valve's Source SDK (source-sdk-2013)'s ragdoll model parsing logic contains a stack-based buffer overflow vulnerability.The tokenizer function `nexttoken` copies characters from an input string into a fixed-size stack buffer without performing bounds checks. When `ParseKeyValue` processes a collisionpair rule longer than the destination buffer (256 bytes), an overflow of the stack buffer `szToken` can occur and overwrite the function return address. A remote attacker can trigger the vulnerable code by supplying a specially crafted ragdoll model which causes the oversized collisionpair rule to be parsed, resulting in remote code execution on affected clients or servers. Valve has addressed this issue in many of their Source games, but independently-developed games must manually apply patch.
CVE-2010-20119 2026-04-15 N/A
CommuniCrypt Mail versions up to and including 1.16 contains a stack-based buffer overflow vulnerability in its ANSMTP.dll and AOSMTP.dll ActiveX controls, specifically within the AddAttachments() method. This method fails to properly validate the length of input strings, allowing data to exceed the bounds of a fixed-size stack buffer. When invoked with an overly long string, the control can corrupt adjacent memory structures, including exception handlers, leading to potential control flow disruption.
CVE-2025-55195 1 Denoland 1 Std 2026-04-15 7.3 High
@std/toml is the Deno Standard Library. Prior to version 1.0.9, an attacker can pollute the prototype chain in Node.js runtime and Browser when parsing untrusted TOML data, thus achieving Prototype Pollution (PP) vulnerability. This is because the library is merging an untrusted object with an empty object, which by default the empty object has the prototype chain. This issue has been patched in version 1.0.9.
CVE-2025-15013 1 Floooh 1 Sokol 2026-04-15 5.3 Medium
A vulnerability was identified in floooh sokol up to 5d11344150973f15e16d3ec4ee7550a73fb995e0. The impacted element is the function _sg_validate_pipeline_desc in the library sokol_gfx.h. Such manipulation leads to stack-based buffer overflow. The attack must be carried out locally. The exploit is publicly available and might be used. This product utilizes a rolling release system for continuous delivery, and as such, version information for affected or updated releases is not disclosed. The name of the patch is b95c5245ba357967220c9a860c7578a7487937b0. It is best practice to apply a patch to resolve this issue.
CVE-2025-52533 1 Amd 36 Amd Ryzen™ Embedded V1000 Series Processors (formerly Codenamed , Athlon 3000 Series Mobile Processors With Radeon Graphics, Epyc 7001 Series Processors and 33 more 2026-04-15 N/A
Improper Access Control in an on-chip debug interface could allow a privileged attacker to enable a debug interface and potentially compromise data confidentiality or integrity.
CVE-2025-36730 1 Windsurf 1 Windsurf 2026-04-15 N/A
A prompt injection vulnerability exists in Windsurft version 1.10.7 in Write mode using SWE-1 model. It is possible to create a file name that will be appended to the user prompt causing Windsurf to follow its instructions.
CVE-2025-25178 2026-04-15 7.8 High
Software installed and run as a non-privileged user may conduct improper GPU system calls to cause kernel system memory corruption.
CVE-2025-24310 2026-04-15 N/A
Improper restriction of rendered UI layers or frames issue exists in HMI ViewJet C-more series, which may allow a remote unauthenticated attacker to trick the product user to perform operations on the product's web pages.
CVE-2009-20003 2 Microsoft, Xenorate 2 Windows, Xenorate 2026-04-15 N/A
Xenorate versions up to and including 2.50, a Windows-based multimedia player, is vulnerable to a stack-based buffer overflow when processing .xpl playlist files. The application fails to properly validate the length of input data, allowing an attacker to craft a malicious .xpl file that overwrites the Structured Exception Handler (SEH) and enables arbitrary code execution. Exploitation requires local interaction, typically by convincing a user to open the crafted file.