Export limit exceeded: 24525 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (24525 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-42940 1 Sap 1 Commoncryptolib 2026-04-15 7.5 High
SAP CommonCryptoLib does not perform necessary boundary checks during pre-authentication parsing of manipulated ASN.1 data over the network. This may result in memory corruption followed by an application crash, hence leading to a high impact on availability. There is no impact on confidentiality or integrity.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-42757 1 Asus 1 Rt-n15u Firmware 2026-04-15 9.8 Critical
Command injection vulnerability in Asus RT-N15U 3.0.0.4.376_3754 allows a remote attacker to execute arbitrary code via the netstat function page.
CVE-2024-3299 2026-04-15 7.8 High
Out-Of-Bounds Write, Use of Uninitialized Resource and Use-After-Free vulnerabilities exist in the file reading procedure in eDrawings from Release SOLIDWORKS 2023 through Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted SLDDRW or SLDPRT file. NOTE: this vulnerability was SPLIT from CVE-2024-1847.
CVE-2024-33008 2026-04-15 4.9 Medium
SAP Replication Server allows an attacker to use gateway for executing some commands to RSSD. This could result in crashing the Replication Server due to memory corruption with high impact on Availability of the system.
CVE-2024-40895 2026-04-15 6.4 Medium
FFRI AMC versions 3.4.0 to 3.5.3 and some OEM products that implement/bundle FFRI AMC versions 3.4.0 to 3.5.3 allow a remote unauthenticated attacker to execute arbitrary OS commands when certain conditions are met in an environment where the notification program setting is enabled and the executable file path is set to a batch file (.bat) or command file (.cmd) extension.
CVE-2025-9494 1 Viessmann 1 Vitogate 300 2026-04-15 N/A
An OS command injection vulnerability has been discovered in the Vitogate 300, which can be exploited by malicious users to compromise affected installations. Specifically, the `/cgi-bin/vitogate.cgi` endpoint is affected, when the `form` JSON parameter is set to `form-0-2`. The vulnerability stems from the fact that that function at offset 0x21c24 does not properly sanitize supplied input before interpolating it into a format string which gets passed to `popen()`. Consequently, an authenticated attacker is able to inject arbitrary OS commands and thus gain code execution on affected devices.
CVE-2025-3362 1 Hgiga 1 Isherlock 2026-04-15 9.8 Critical
The web service of iSherlock from HGiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server.
CVE-2025-24351 2026-04-15 8.8 High
A vulnerability in the “Remote Logging” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to execute arbitrary OS commands in the context of user “root” via a crafted HTTP request.
CVE-2025-1268 2026-04-15 9.4 Critical
Out-of-bounds vulnerability in EMF Recode processing of Generic Plus PCL6 Printer Driver / Generic Plus UFR II Printer Driver / Generic Plus LIPS4 Printer Driver / Generic Plus LIPSLX Printer Driver / Generic Plus PS Printer Driver / Generic FAX Printer Driver / UFRII LT Printer Driver / CARPS2 Printer Driver / PDF Driver / LIPS4 Printer Driver / LIPSLX Printer Driver / UFR II Printer Driver / PS Printer Driver / PCL6 Printer Driver
CVE-2024-20295 1 Cisco 1 Integrated Management Controller 2026-04-15 8.8 High
A vulnerability in the CLI of the Cisco Integrated Management Controller (IMC) could allow an authenticated, local attacker to perform command injection attacks on the underlying operating system and elevate privileges to root. To exploit this vulnerability, the attacker must have read-only or higher privileges on an affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by submitting a crafted CLI command. A successful exploit could allow the attacker to elevate privileges to root.
CVE-2024-39927 2026-04-15 8.2 High
Out-of-bounds write vulnerability exists in Ricoh MFPs and printers. If a remote attacker sends a specially crafted request to the affected products, the products may be able to cause a denial-of-service (DoS) condition and/or user's data may be destroyed.
CVE-2025-35028 1 Hexstrike-ai Project 1 Hexstrike-ai 2026-04-15 9.1 Critical
By providing a command-line argument starting with a semi-colon ; to an API endpoint created by the EnhancedCommandExecutor class of the HexStrike AI MCP server, the resultant composed command is executed directly in the context of the MCP server’s normal privilege; typically, this is root. There is no attempt to sanitize these arguments in the default configuration of this MCP server at the affected version (as of commit 2f3a5512 in September of 2025).
CVE-2025-32107 2026-04-15 N/A
OS command injection vulnerability exists in Deco BE65 Pro firmware versions prior to "Deco BE65 Pro(JP)_V1_1.1.2 Build 20250123". If this vulnerability is exploited, an arbitrary OS command may be executed by the user who can log in to the device.
CVE-2024-1848 2026-04-15 7.8 High
Heap-based Buffer Overflow, Memory Corruption, Out-Of-Bounds Read, Out-Of-Bounds Write, Stack-based Buffer Overflow, Type Confusion, Uninitialized Variable, Use-After-Free vulnerabilities exist in the file reading procedure in SOLIDWORKS Desktop on Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted CATPART, DWG, DXF, IPT, JT, SAT, SLDDRW, SLDPRT, STL, STP, X_B or X_T file.
CVE-2025-24971 2026-04-15 N/A
DumpDrop is a stupid simple file upload application that provides an interface for dragging and dropping files. An OS Command Injection vulnerability was discovered in the DumbDrop application, `/upload/init` endpoint. This vulnerability could allow an attacker to execute arbitrary code remotely when the **Apprise Notification** enabled. This issue has been addressed in commit `4ff8469d` and all users are advised to patch. There are no known workarounds for this vulnerability.
CVE-2025-34152 1 Shenzhen Aitemi 2 M300, M300 Wifi Repeater 2026-04-15 N/A
An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) via the 'time' parameter of the '/protocol.csp?' endpoint. The input is processed by the internal date '-s' command without rebooting or disrupting HTTP service. Unlike other injection points, this vector allows remote compromise without triggering visible configuration changes.
CVE-2024-38511 2026-04-15 7.2 High
A privilege escalation vulnerability was discovered in an upload processing functionality of XCC that could allow an authenticated XCC user with elevated privileges to perform command injection via specially crafted file uploads.
CVE-2025-43875 1 Johnsoncontrols 5 Istar Edge G2, Istar Ultra, Istar Ultra G2 and 2 more 2026-04-15 N/A
Under certain circumstances a successful exploitation could result in access to the device.