Export limit exceeded: 56045 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (56045 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-47271 | 2026-04-15 | N/A | ||
| The OZI action is a GitHub Action that publishes releases to PyPI and mirror releases, signature bundles, and provenance in a tagged release. In versions 1.13.2 through 1.13.5, potentially untrusted data flows into PR creation logic. A malicious actor could construct a branch name that injects arbitrary code. This is patched in 1.13.6. As a workaround, one may downgrade to a version prior to 1.13.2. | ||||
| CVE-2025-3791 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability classified as critical was found in symisc UnQLite up to 957c377cb691a4f617db9aba5cc46d90425071e2. This vulnerability affects the function jx9MemObjStore of the file /data/src/benchmarks/unqlite/unqlite.c. The manipulation leads to heap-based buffer overflow. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. | ||||
| CVE-2025-13084 | 1 Opto 22 | 3 Groov View Server, Grv-epic-pr1 Firmware, Grv-epic-pr2 Firmware | 2026-04-15 | 7.6 High |
| The users endpoint in the groov View API returns a list of all users and associated metadata including their API keys. This endpoint requires an Editor role to access and will display API keys for all users, including Administrators. | ||||
| CVE-2025-37149 | 1 Hpe | 1 Proliant Rl300 Gen11 | 2026-04-15 | 6 Medium |
| A potential out-of-bound reads vulnerability in HPE ProLiant RL300 Gen11 Server's UEFI firmware. | ||||
| CVE-2025-5124 | 2026-04-15 | 8.1 High | ||
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". | ||||
| CVE-2024-43659 | 2026-04-15 | 7.2 High | ||
| After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2021-47901 | 1 Maurosoria | 1 Dirsearch | 2026-04-15 | 9.8 Critical |
| Dirsearch 0.4.1 contains a CSV injection vulnerability when using the --csv-report flag that allows attackers to inject formulas through redirected endpoints. Attackers can craft malicious server redirects with comma-separated paths containing Excel formulas to manipulate the generated CSV report. | ||||
| CVE-2020-37193 | 2 Krylack, Top Password Software | 2 Zip Password Recovery, Zip Password Recovery | 2026-04-15 | 7.5 High |
| ZIP Password Recovery 2.30 contains a denial of service vulnerability that allows attackers to crash the application by providing maliciously crafted input. Attackers can create a specially prepared text file with specific characters to trigger an application crash when selecting a ZIP file. | ||||
| CVE-2025-31929 | 2026-04-15 | 4.2 Medium | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. | ||||
| CVE-2025-27708 | 1 Intel | 1 Converged Security Management Engine Firmware | 2026-04-15 | 4.1 Medium |
| Out-of-bounds read in the firmware for some Intel(R) Converged Security and Management Engine (CSME) Firmware (FW) within Ring 0: Kernel may allow an information disclosure. System software adversary with a privileged user combined with a low complexity attack may enable data exposure. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (none) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. | ||||
| CVE-2024-39323 | 1 Aimeos | 1 Ai-admin-graphql | 2026-04-15 | 7.1 High |
| aimeos/ai-admin-graphql is the Aimeos GraphQL API admin interface. Starting in version 2022.04.01 and prior to versions 2022.10.10, 2023.10.6, and 2024.04.6, an improper access control vulnerability allows an editor to modify and take over an admin account in the back end. Versions 2022.10.10, 2023.10.6, and 2024.04.6 fix this issue. | ||||
| CVE-2025-20237 | 1 Cisco | 2 Adaptive Security Appliance Software, Firepower Threat Defense Software | 2026-04-15 | 6 Medium |
| A vulnerability in Cisco Secure Firewall Adaptive Security Appliance (ASA) Software and Cisco Secure Firewall Threat Defense (FTD) Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system with root-level privileges. To exploit this vulnerability, the attacker must have valid administrative credentials. This vulnerability is due to insufficient input validation of commands that are supplied by the user. An attacker could exploit this vulnerability by authenticating to a device and submitting crafted input for specific commands. A successful exploit could allow the attacker to execute commands on the underlying operating system as root. | ||||
| CVE-2025-42909 | 1 Sap | 1 Cloud Appliance Library Appliances | 2026-04-15 | 3 Low |
| SAP Cloud Appliance Library Appliances allows an attacker with high privileges to leverage an insecure S/4HANA default profile setting in an existing SAP CAL appliances to gain access to other appliances. This has low impact on confidentiality of the application, integrity and availability is not impacted. | ||||
| CVE-2025-59365 | 1 Asus | 1 Router | 2026-04-15 | N/A |
| A stack buffer overflow vulnerability has been identified in certain router models. An authenticated attacker may trigger this vulnerability by sending a crafted request, potentially impacting the availability of the device. Refer to the ' Security Update for ASUS Router Firmware' section on the ASUS Security Advisory for more information. | ||||
| CVE-2025-0012 | 1 Amd | 2 Epyc 9005 Series Processors, Epyc Embedded 9005 Series Processors | 2026-04-15 | N/A |
| Improper handling of overlap between the segmented reverse map table (RMP) and system management mode (SMM) memory could allow a privileged attacker corrupt or partially infer SMM memory resulting in loss of integrity or confidentiality. | ||||
| CVE-2022-4969 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability, which was classified as critical, has been found in bwoodsend rockhopper up to 0.1.2. Affected by this issue is the function count_rows of the file rockhopper/src/ragged_array.c of the component Binary Parser. The manipulation of the argument raw leads to buffer overflow. Local access is required to approach this attack. Upgrading to version 0.2.0 is able to address this issue. The name of the patch is 1a15fad5e06ae693eb9b8908363d2c8ef455104e. It is recommended to upgrade the affected component. The identifier of this vulnerability is VDB-266312. | ||||
| CVE-2025-22885 | 1 Intel | 1 Tdx Module | 2026-04-15 | 4.7 Medium |
| Improper buffer restrictions in the firmware for the TDX Module may allow an escalation of privilege. System software adversary with a privileged user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (low) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. | ||||
| CVE-2023-43694 | 1 Malwarebytes | 1 Malwarebytes | 2026-04-15 | 5.2 Medium |
| An issue was discovered in Malwarebytes 4.6.14.326 and before and 5.1.5.116 and before (and Nebula 2020-10-21 and later). An Out of bounds read in several disassembling utilities causes stability issues and denial of service. | ||||
| CVE-2025-0960 | 2026-04-15 | 9.8 Critical | ||
| AutomationDirect C-more EA9 HMI contains a function with bounds checks that can be skipped, which could result in an attacker abusing the function to cause a denial-of-service condition or achieving remote code execution on the affected device. | ||||
| CVE-2025-66559 | 1 Taiko | 1 Taiko-mono | 2026-04-15 | N/A |
| Taiko Alethia is an Ethereum-equivalent, permissionless, based rollup designed to scale Ethereum without compromising its fundamental properties. In 2.3.1 and earlier, TaikoInbox._verifyBatches (packages/protocol/contracts/layer1/based/TaikoInbox.sol:627-678) advanced the local tid to whatever transition matched the current blockHash before knowing whether that batch would actually be verified. When the loop later broke (e.g., cooldown window not yet passed or transition invalidated), the function still wrote that newer tid into batches[lastVerifiedBatchId].verifiedTransitionId after decrementing batchId. Result: the last verified batch could end up pointing at a transition index from the next batch (often zeroed), corrupting the verified chain pointer. | ||||