| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Insyde IHISI function 0x49 can restore factory defaults for certain UEFI variables without further authentication by default, which could lead to a possible roll-back attack in certain platforms. This is fixed in: kernel 5.2, version 05.29.19; kernel 5.3, version 05.38.19; kernel 5.4, version 05.46.19; kernel 5.5, version 05.54.19; kernel 5.6, version 05.61.19. |
| ESCAM QD-900 WIFI HD cameras contain an unauthenticated configuration disclosure vulnerability in the /web/cgi-bin/hi3510/backup.cgi endpoint. The endpoint allows remote download of a compressed configuration backup without requiring authentication or authorization. The exposed backup can include administrative credentials and other sensitive device settings, enabling an unauthenticated remote attacker to obtain information that may facilitate further compromise of the camera or connected network. |
| An issue was discovered in Cicool builder 3.4.4 allowing attackers to reset the administrator's password via the /administrator/auth/reset_password endpoint. |
| FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication. |
| In version 0.4.1 of danswer-ai/danswer, a vulnerability exists where a basic user can create credentials and link them to an existing connector. This issue arises because the system allows an unauthenticated attacker to sign up with a basic account and perform actions that should be restricted to admin users. This can lead to excessive resource consumption, potentially resulting in a Denial of Service (DoS) and other significant issues, impacting the system's stability and security. |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| A code injection vulnerability exists in Yonyou UFIDA NC v6.5 and prior due to the exposure of the BeanShell testing servlet (bsh.servlet.BshServlet) without proper access controls. The servlet allows unauthenticated remote attackers to execute arbitrary Java code via the bsh.script parameter. This can be exploited to run system commands and ultimately gain full control over the target server. The issue is rooted in a third-party JAR component bundled with the application, and the servlet is accessible without authentication on vulnerable installations. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC. |
| Multiple FCNT Android devices provide the original security features such as "privacy mode" where arbitrary applications can be set not to be displayed, etc.
Under certain conditions, and when an attacker can directly operate the device which its screen is unlocked by a user, the provided security features' setting pages may be exposed and/or the settings may be altered, without authentication. For example, specific applications in the device configured to be hidden may be displayed and/or activated. |
| Insufficient authentication in user account management in Yugabyte Platform allows local network attackers with a compromised user session to change critical security information without re-authentication. An attacker with user session and access to application can modify settings such as password and email without being prompted for the current password, enabling account takeover. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information. |
| A path traversal vulnerability has been identified in WebDAV, which may allow unauthenticated remote attackers to impact the integrity of the device.
Refer to the ' Security Update for ASUS Router Firmware' section on the ASUS Security Advisory for more information. |
| In RPyC before 6.0.0, when a server exposes a method that calls the attribute named __array__ for a client-provided netref (e.g., np.array(client_netref)), a remote attacker can craft a class that results in remote code execution. |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |
| Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information. |
| The devices do not implement any authentication for the web interface or the MQTT server. An attacker who has network access to the device immediately gets administrative access to the devices and can perform arbitrary administrative actions and reconfigure the devices or potentially gain access to sensitive data. |
| Toshiba printers provides API without authentication for internal access. A local attacker can bypass authentication in applications, providing administrative access. As for the affected products/models/versions, see the reference URL. |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| Nedap Librix Ecoreader
is missing authentication for critical functions that could allow an
unauthenticated attacker to potentially execute malicious code. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| A Missing Authentication for Critical Function vulnerability in the GRUB configuration used B&R APROL <4.4-01 may allow an unauthenticated physical attacker to alter the boot configuration of the operating system. |