Export limit exceeded: 418227 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (3818 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-8057 | 1 Danswer-ai | 1 Danswer | 2026-04-15 | N/A |
| In version 0.4.1 of danswer-ai/danswer, a vulnerability exists where a basic user can create credentials and link them to an existing connector. This issue arises because the system allows an unauthenticated attacker to sign up with a basic account and perform actions that should be restricted to admin users. This can lead to excessive resource consumption, potentially resulting in a Denial of Service (DoS) and other significant issues, impacting the system's stability and security. | ||||
| CVE-2023-1083 | 1 Welotec | 5 Tk515l, Tk525l, Tk525u and 2 more | 2026-04-15 | 9.8 Critical |
| An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates. | ||||
| CVE-2024-43798 | 1 Jpillora | 1 Chisel | 2026-04-15 | 8.6 High |
| Chisel is a fast TCP/UDP tunnel, transported over HTTP, secured via SSH. The Chisel server doesn't ever read the documented `AUTH` environment variable used to set credentials, which allows any unauthenticated user to connect, even if credentials were set. Anyone running the Chisel server that is using the `AUTH` environment variable to specify credentials to authenticate against is affected by this vulnerability. Chisel is often used to provide an entrypoint to a private network, which means services that are gated by Chisel may be affected. Additionally, Chisel is often used for exposing services to the internet. An attacker could MITM requests by connecting to a Chisel server and requesting to forward traffic from a remote port. This issue has been addressed in release version 1.10.0. All users are advised to upgrade. There are no known workarounds for this vulnerability. | ||||
| CVE-2025-5871 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-2567 | 2026-04-15 | 9.8 Critical | ||
| An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation. | ||||
| CVE-2024-31684 | 2026-04-15 | 3.5 Low | ||
| Incorrect access control in the fingerprint authentication mechanism of Bitdefender Mobile Security v4.11.3-gms allows attackers to bypass fingerprint authentication due to the use of a deprecated API. | ||||
| CVE-2020-12491 | 2026-04-15 | N/A | ||
| Improper control of framework service permissions with possibility of some sensitive device information leakage. | ||||
| CVE-2014-125124 | 3 Artica, Pandora Fms, Pandorafms | 4 Pandora Fms, Pandora Fms, Artica Pandora Fms and 1 more | 2026-04-15 | N/A |
| An unauthenticated remote command execution vulnerability exists in Pandora FMS versions up to and including 5.0RC1 via the Anyterm web interface, which listens on TCP port 8023. The anyterm-module endpoint accepts unsanitized user input via the p parameter and directly injects it into a shell command, allowing arbitrary command execution as the pandora user. In certain versions (notably 4.1 and 5.0RC1), the pandora user can elevate privileges to root without a password using a chain involving the artica user account. This account is typically installed without a password and is configured to run sudo without authentication. Therefore, full system compromise is possible without any credentials. | ||||
| CVE-2024-21846 | 2026-04-15 | 5.3 Medium | ||
| An unauthenticated attacker can reset the board and stop transmitter operations by sending a specially-crafted GET request to the command.cgi gateway, resulting in a denial-of-service scenario. | ||||
| CVE-2024-51362 | 1 Lsc Smart Connect | 1 Indoor Camera Firmware | 2026-04-15 | 6.5 Medium |
| The LSC Smart Connect Indoor IP Camera V7.6.32 is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security. No credentials or special permissions are required, and access can be gained remotely over the network. | ||||
| CVE-2024-48791 | 1 Plug N Play Camera | 1 Plug N Play Camera | 2026-04-15 | 7.5 High |
| An issue in Plug n Play Camera com.starvedia.mCamView.zwave 5.5.1 allows a remote attacker to obtain sensitive information via the firmware update process | ||||
| CVE-2024-23943 | 2026-04-15 | 9.1 Critical | ||
| An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected. | ||||
| CVE-2025-59780 | 1 General Industrial Controls | 1 Lynx+ Gateway | 2026-04-15 | 7.5 High |
| General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which could allow an attacker to send GET requests to obtain sensitive device information. | ||||
| CVE-2025-40771 | 1 Siemens | 6 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 3 more | 2026-04-15 | 9.8 Critical |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. | ||||
| CVE-2021-47710 | 1 Commax | 1 Smart Home System | 2026-04-15 | N/A |
| COMMAX Smart Home System is a smart IoT home solution that allows an unauthenticated attacker to disclose RTSP credentials in plain-text by exploiting the /overview.asp endpoint. Attackers can access sensitive information, including login credentials and DVR settings, by submitting a GET request to this endpoint. | ||||
| CVE-2025-34101 | 1 Plex | 1 Media Server Firmware | 2026-04-15 | N/A |
| An unauthenticated command injection vulnerability exists in Serviio Media Server versions 1.4 through 1.8 on Windows, in the /rest/action API endpoint exposed by the console component (default port 23423). The checkStreamUrl method accepts a VIDEO parameter that is passed unsanitized to a call to cmd.exe, enabling arbitrary command execution under the privileges of the web server. No authentication is required to exploit this issue, as the REST API is exposed by default and lacks access controls. | ||||
| CVE-2025-34100 | 2026-04-15 | N/A | ||
| An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngine’s improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution. | ||||
| CVE-2025-32738 | 2026-04-15 | 5.3 Medium | ||
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. | ||||
| CVE-2025-36756 | 1 Solax | 1 Solax Cloud | 2026-04-15 | N/A |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. | ||||
| CVE-2025-0355 | 2026-04-15 | 7.5 High | ||
| Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network. | ||||