| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| NVIDIA Display Driver for Windows and Linux contains a vulnerability in a video decoder, where an attacker might cause an out-of-bounds read. A successful exploit of this vulnerability might lead to information disclosure or denial of service. |
|
A buffer overflow vulnerability was reported
in a system recovery bootloader that was part of the Lenovo preloaded Windows 7 and 8 operating systems from 2012 to 2014
that could allow a privileged attacker with local access to execute arbitrary code.
|
| There is a buffer overflow vulnerability in the underlying L2/L3 Management service that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba's access point management protocol) UDP port (8211). Successful exploitation of this vulnerability results in the ability to execute arbitrary code as a privileged user on the underlying operating system.
|
| A malformed 802.15.4 packet causes a buffer overflow to occur leading to an assert and a denial of service. A watchdog reset clears the error condition automatically. |
| The bson_string_append function in MongoDB C Driver may be vulnerable to a buffer overflow where the function might attempt to allocate too small of buffer and may lead to memory corruption of neighbouring heap memory. This issue affects libbson versions prior to 1.27.1 |
| A heap-based buffer overflow vulnerability has been identified in the Postscript interpreter in various Lexmark devices. This vulnerability can be leveraged by an attacker to execute arbitrary code as an unprivileged user. |
| A Buffer Overflow vulnerability in the local_app_set_router_wifi_SSID_PWD function of Vilo 5 Mesh WiFi System <= 5.16.1.33 allows remote, unauthenticated attackers to execute arbitrary code via a password field larger than 64 bytes in length. |
| A Buffer Overflow vulnerability in the local_app_set_router_wan function of Vilo 5 Mesh WiFi System <= 5.16.1.33 allows remote, unauthenticated attackers to execute arbitrary code via pppoe_username and pppoe_password fields being larger than 128 bytes in length. |
| A Buffer Overflow vulnerabilty in the local_app_set_router_token function of Vilo 5 Mesh WiFi System <= 5.16.1.33 allows remote, unauthenticated attackers to execute arbitrary code via sscanf reading the token and timezone JSON fields into a fixed-length buffer. |
| Insecure permissions in volcano v1.8.2 allows attackers to access sensitive data and escalate privileges by obtaining the service account's token. |
| eLinkSmart Hidden Smart Cabinet Lock 2024-05-22 has Incorrect Access Control and fails to perform an authorization check which can lead to card duplication and other attacks. |
| An issue was discovered on Supermicro BMC firmware in select X11, X12, H12, B12, X13, H13, and B13 motherboards (and CMM6 modules). An unauthenticated user can post crafted data to the interface that triggers a stack buffer overflow, and may lead to arbitrary remote code execution on a BMC. |
| Rubo DICOM Viewer 2.0 contains a buffer overflow vulnerability in the DICOM server name input field that allows attackers to overwrite Structured Exception Handler (SEH). Attackers can craft a malicious text file with carefully constructed payload to execute arbitrary code by overwriting SEH and triggering remote code execution. |
| The <redacted>.so library, which is used by <redacted>, is
vulnerable to a buffer overflow in the code that handles the deletion
of certificates. This buffer overflow can be triggered by providing a
long file path to the <redacted> action of the <redacted>.exe CGI binary or
to the <redacted>.sh CGI script. This binary or script will write this
file path to <redacted>, which is then
read by <redacted>.so
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – An attacker will have to find this exploit by
either obtaining the binaries involved in this vulnerability, or by trial
and error. Furthermore, the attacker will need a (low privilege)
account to gain access to the <redacted>.exe CGI binary or <redacted>.sh
script to trigger the vulnerability, or convince a user with such access
send an HTTP request that triggers it.
Impact: High – The <redacted> process, which we assume is
responsible for OCPP communication, will keep crashing after
performing the exploit. This happens because the buffer overflow
causes the process to segfault before
<redacted> is removed. This means that,
even though <redacted> is automatically restarted, it will crash
again as soon as it tries to parse the text file.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I). |
| Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation.
This issue affects FLXEON: through 9.3.5. |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
| Improper finite state machines (FSMs) in the hardware logic in some 4th and 5th Generation Intel(R) Xeon(R) Processors may allow an authorized user to potentially enable denial of service via local access. |
| Florent Thiéry has found that selected Axis devices were vulnerable to handling certain ethernet frames which could lead to the Axis device becoming unavailable in the network.
Axis has released patched AXIS OS versions for the highlighted flaw for products that are still under AXIS OS software support. Please refer to the Axis security advisory for more information and solution. |
| An issue was discovered on certain Nuki Home Solutions devices. There is a buffer overflow over the encrypted token parsing logic in the HTTP service that allows remote code execution. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| An invalid memory access when handling the ProtocolIE_ID field of E-RAB Release Indication messages in Athonet vEPC MME v11.4.0 allows attackers to cause a Denial of Service (DoS) to the cellular network by repeatedly initiating connections and sending a crafted payload. |