| An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges. |
| An elevation of privilege vulnerability in the Android media framework (mediaanalytics). Product: Android. Versions: 8.0. Android ID: A-65540999. |
| IBM Security Access Manager for Web could allow an authenticated user to gain access to highly sensitive information due to incorrect file permissions. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/passwd permissions. |
| In Flatpak before 0.8.7, a third-party app repository could include malicious apps that contain files with inappropriate permissions, for example setuid or world-writable. The files are deployed with those permissions, which would let a local attacker run the setuid executable or write to the world-writable location. In the case of the "system helper" component, files deployed as part of the app are owned by root, so in the worst case they could be setuid root. |
| Xen through 4.8.x mishandles page transfer, which allows guest OS users to obtain privileged host OS access, aka XSA-217. |
| During installation of Ambari 2.4.0 through 2.4.2, Ambari Server artifacts are not created with proper ACLs. |
| IBM WebSphere Application Server 7.0, 8.0, 8.5, and 9.0 might create files using the default permissions instead of the customized permissions when custom startup scripts are used. A local attacker could exploit this to gain access to files with an unknown impact. IBM X-Force ID: 127153. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/storage_account_root permissions. |
| The SecEmailComposer/EmailComposer application in the Samsung S6 Edge before the October 2015 MR uses weak permissions for the com.samsung.android.email.intent.action.QUICK_REPLY_BACKGROUND service action, which might allow remote attackers with knowledge of the local email address to obtain sensitive information via a crafted application that sends a crafted intent. |
| The AlarmService component in HwVmall with software earlier than 1.5.2.0 versions has no control over calling permissions, allowing any third party to call. An attacker can construct a malicious application to call it. Consequently, alert music will be played suddenly, compromising user experience. |
| Polycom BToE Connector before 3.0.0 uses weak permissions (Everyone: Full Control) for "Program Files (x86)\polycom\polycom btoe connector\plcmbtoesrv.exe," which allows local users to gain privileges via a Trojan horse file. |
| The BIOS in Intel Compute Stick systems based on 6th Gen Intel Core processors prior to version CC047 may allow an attacker with physical access to the system to gain access to personal information. |
| An issue was discovered in Logpoint 7.1 before 7.1.2. The daily executed cron file clean_secbi_old_logs is writable by all users and is executed as root, leading to privilege escalation. |
| Sourcecodester Human Resource Management System 1.0 is vulnerable to Insecure Permissions resulting in privilege escalation. |
| Insecure permission vulnerability in /hrm/leaverequest.php in SourceCodester Human Resource Management System 1.0 allow attackers to approve or reject leave ticket. |
| Sysmac Studio installs executables in a directory with poor permissions. This can allow a locally-authenticated attacker to overwrite files which will result in code execution with privileges of a different user. |
| Apiman 1.5.7 through 2.2.3.Final has insufficient checks for read permissions within the Apiman Manager REST API. The root cause of the issue is the Apiman project's accidental acceptance of a large contribution that was not fully compatible with the security model of Apiman versions before 3.0.0.Final. Because of this, 3.0.0.Final is not affected by the vulnerability. |
| Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to an incorrect default permission in the DIAEnergie application, which may allow an attacker to plant new files (such as DLLs) or replace existing executable files. |