Search Results (111035 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-25645 1 Zte 10 Up T2 4k, Up T2 4k Firmware, Zxv10 B860h V5d0 and 7 more 2024-12-12 7.7 High
There is a permission and access control vulnerability in some ZTE AndroidTV STBs. Due to improper permission settings, non-privileged application can perform functions that are protected with signature/privilege-level permissions. Exploitation of this vulnerability could clear personal data and applications on the user's device, affecting device operation.
CVE-2024-12484 1 Codezips 1 Technical Discussion Forum 2024-12-12 7.3 High
A vulnerability classified as critical was found in Codezips Technical Discussion Forum 1.0. This vulnerability affects unknown code of the file /signuppost.php. The manipulation of the argument Username leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.
CVE-2024-2764 2 Tenda, Tendacn 3 Ac10u, Ac10u Firmware, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2763 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2711 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2710 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2709 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2708 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2706 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2705 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2704 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2703 1 Tenda 2 Ac10u, Ac10u Firmware 2024-12-12 8.8 High
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-2492 1 Querywall Plug\'n Play Firewall Project 1 Querywall Plug\'n Play Firewall 2024-12-12 7.2 High
The QueryWall: Plug'n Play Firewall WordPress plugin through 1.1.1 does not properly sanitise and escape a parameter before using it in a SQL statement, leading to a SQL injection exploitable by high privilege users such as admin.
CVE-2023-2359 1 Themepunch 1 Slider Revolution 2024-12-12 8.8 High
The Slider Revolution WordPress plugin through 6.6.12 does not check for valid image files upon import, leading to an arbitrary file upload which may be escalated to Remote Code Execution in some server configurations.
CVE-2023-24243 1 Cdata 1 Arc 2024-12-12 7.5 High
CData RSB Connect v22.0.8336 was discovered to contain a Server-Side Request Forgery (SSRF).
CVE-2022-4149 2 Microsoft, Netskope 2 Windows, Netskope 2024-12-12 7 High
The Netskope client service (prior to R96) on Windows runs as NT AUTHORITY\SYSTEM which writes log files to a writable directory (C:\Users\Public\netSkope) for a standard user. The files are created and written with a SYSTEM account except one file (logplaceholder) which inherits permission giving all users full access control list. Netskope client restricts access to this file by allowing only read permissions as a standard user. Whenever the Netskope client service restarts, it deletes the logplaceholder and recreates, creating a race condition, which can be exploited by a malicious local user to create the file and set ACL permissions on the file. Once the file is created by a malicious user with proper ACL permissions, all files within C:\Users\Public\netSkope\ becomes modifiable by the unprivileged user. By using Windows pseudo-symlink, these files can be pointed to other places in the system and thus malicious users will be able to elevate privileges.
CVE-2023-2847 1 Eset 3 Cyber Security, Endpoint Antivirus, Server Security 2024-12-12 7.8 High
During internal security analysis, a local privilege escalation vulnerability has been identified. On a machine with the affected ESET product installed, it was possible for a user with lower privileges due to improper privilege management to trigger actions with root privileges. ESET remedied this possible attack vector and has prepared new builds of its products that are no longer susceptible to this vulnerability.
CVE-2024-43053 1 Qualcomm 40 Fastconnect 6700, Fastconnect 6700 Firmware, Fastconnect 6900 and 37 more 2024-12-12 7.8 High
Memory corruption while invoking IOCTL calls from user space to read WLAN target diagnostic information.
CVE-2024-43052 1 Qualcomm 185 205 Mobile Platform, 205 Mobile Platform Firmware, 215 Mobile Platform and 182 more 2024-12-12 7.8 High
Memory corruption while processing API calls to NPU with invalid input.
CVE-2024-43050 1 Qualcomm 109 Aqt1000, Aqt1000 Firmware, Fastconnect 6200 and 106 more 2024-12-12 7.8 High
Memory corruption while invoking IOCTL calls from user space to issue factory test command inside WLAN driver.