| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| win-cli-mcp-server resolveCommandPath Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of win-cli-mcp-server. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the implementation of the resolveCommandPath method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-27787. |
| NVIDIA nvJPEG2000 library contains a vulnerability where an attacker can cause an out-of-bounds write issue by means of a specially crafted JPEG2000 file. A successful exploit of this vulnerability might lead to code execution and data tampering. |
| squid/cachemgr.cgi in Webmin before 2.600 does not properly quote arguments. This is relevant if Webmin's Squid module and its Cache Manager feature are available, and an untrusted party is able to authenticate to Webmin and has certain Cache Manager permissions (the "cms" security option). |
| Software installed and run as a non-privileged user may conduct improper GPU system calls resulting in platform instability and reboots. |
| An issue discovered in the DeviceIoControl component in ASUS Fan_Xpert before v.10013 allows an attacker to execute arbitrary code via crafted IOCTL requests. |
| FLIR Thermal Camera FC-S/PT firmware version 8.0.0.64 contains an authenticated OS command injection vulnerability that allows attackers to execute shell commands with root privileges. Authenticated attackers can inject arbitrary shell commands through unvalidated input parameters to gain complete control of the thermal camera system. |
| Finit provides fast init for Linux systems. Finit's urandom plugin has a heap buffer overwrite vulnerability at boot which leads to it overwriting other parts of the heap, possibly causing random instabilities and undefined behavior. The urandom plugin is enabled by default, so this bug affects everyone using Finit 4.2 or later that do not explicitly disable the plugin at build time. This bug is fixed in Finit 4.12. Those who cannot upgrade or backport the fix to urandom.c are strongly recommended to disable the plugin in the call to the `configure` script. |
| MicroDicom
DICOM Viewer suffers from an out-of-bounds write vulnerability. Remote attackers are able to exploit this issue to potentially execute arbitrary code on affected installations of DICOM Viewer. User interaction is required to exploit the vulnerability in that the user must either visit a malicious website or open a malicious DICOM file locally. |
| Erroneously using an all-zero seed for RSA-OEAP padding instead of the generated random bytes, in Oberon microsystems AG’s Oberon PSA Crypto library in all versions up to 1.5.1, results in deterministic RSA and thus in a loss of confidentiality for guessable messages, recognition of repeated messages, and loss of security proofs. |
| ThinPLUS developed by ThinPLUS has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. |
| Contec Health CMS8000 Patient Monitor is vulnerable to an out-of-bounds write, which could allow an attacker to send specially formatted UDP requests in order to write arbitrary data. This could result in remote code execution. |
| COMMAX UMS Client ActiveX Control 1.7.0.2 contains a heap-based buffer overflow vulnerability that allows attackers to execute arbitrary code by providing excessively long string arrays through multiple functions. Attackers can exploit improper boundary validation in CNC_Ctrl.dll to cause heap corruption and potentially gain system-level access. |
| Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the software keyboard function (hereinafter referred to as "keypad function") of Mitsubishi Electric GENESIS64 versions 10.97.2 CFR3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 CFR3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 CFR3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 CFR3 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 CFR3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 CFR3 and prior, and Mitsubishi Electric MC Works64 all versions allows a local attacker to execute arbitrary executable files (EXE) when a legitimate user uses the keypad function by tampering with the configuration file for the function. This could allow the attacker to disclose, tamper with, delete, or destroy information stored on the PC where the affected product is installed, or cause a denial-of-service (DoS) condition on the system, through the execution of the EXE. |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Mesh Wi-Fi router RP562B firmware version v1.0.2 and earlier. If this vulnerability is exploited, a network-adjacent authenticated attacker may execute an arbitrary OS command. |
| The web service of iSherlock from HGiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. |
| Missing input validation and OS command integration of the input in the utnserver Pro, utnserver ProMAX, INU-100 web-interface allows authenticated command injection.This issue affects utnserver Pro, utnserver ProMAX, INU-100 version 20.1.22 and below. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Firmware in SDMC NE6037 routers prior to version 7.1.12.2.44 has a network diagnostics tool vulnerable to a shell command injection attacks.
In order to exploit this vulnerability, an attacker has to log in to the router's administrative portal, which by default is reachable only via LAN ports. |
| mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system. |
| Under certain circumstances a successful exploitation could result in access to the device. |