| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| COMMAX Smart Home System allows an unauthenticated attacker to change configuration and cause denial-of-service through the setconf endpoint. Attackers can trigger a denial-of-service scenario by sending a malformed request to the setconf endpoint. |
| The attacker may obtain root access by connecting to the UART port and this vulnerability requires the attacker to have the physical access to the device.
This issue affects Tapo D230S1 V1.20: before 1.2.2 Build 20250907. |
| Incorrect access control in Shenzhen Tuoshi Network Communications Co.,Ltd 5G CPE Router NR500-EA RG500UEAABxCOMSLICv3.2.2543.12.18 allows attackers to access the SSH protocol without authentication. |
| The LSC Smart Connect Indoor IP Camera V7.6.32 is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security. No credentials or special permissions are required, and access can be gained remotely over the network. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network. |
| A remote code execution vulnerability exists in CryptoLog (PHP version, discontinued since 2009) due to a chained exploitation of SQL injection and command injection vulnerabilities. An unauthenticated attacker can gain shell access as the web server user by first exploiting a SQL injection flaw in login.php to bypass authentication, followed by command injection in logshares_ajax.php to execute arbitrary operating system commands.
The login bypass is achieved by submitting crafted SQL via the user POST parameter. Once authenticated, the attacker can abuse the lsid POST parameter in the logshares_ajax.php endpoint to inject and execute a command using $(...) syntax, resulting in code execution under the web context.
This exploitation path does not exist in the ASP.NET version of CryptoLog released since 2009. |
| An unauthenticated command injection vulnerability exists in Serviio Media Server versions 1.4 through 1.8 on Windows, in the /rest/action API endpoint exposed by the console component (default port 23423). The checkStreamUrl method accepts a VIDEO parameter that is passed unsanitized to a call to cmd.exe, enabling arbitrary command execution under the privileges of the web server. No authentication is required to exploit this issue, as the REST API is exposed by default and lacks access controls. |
| An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngineās improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution. |
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. |
| Burk Technology ARC Solo's password change mechanism can be utilized without proper
authentication procedures, allowing an attacker to take over the device.
A password change request can be sent directly to the device's HTTP
endpoint without providing valid credentials. The system does not
enforce proper authentication or session validation, allowing the
password change to proceed without verifying the request's legitimacy. |
| An issue in the Arcadyan Livebox Fibra PRV3399B_B_LT allows a remote or local attacker to modify the GPON link value without authentication, causing an internet service disruption via the /firstconnection.cgi endpoint. |
| By default, the Packet Power Monitoring and Control Web Interface do not
enforce authentication mechanisms. This vulnerability could allow
unauthorized users to access and manipulate monitoring and control
functions. |
| Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network. |
| WorkOS Hosted AuthKit before 2025-01-07 allows a password authentication MFA bypass (by enrolling a new authentication factor) when the attacker knows the user's password. No exploitation occurred. |
| A vulnerability was identified in huggingface LeRobot up to 0.3.3. Affected by this vulnerability is an unknown functionality of the file lerobot/common/robot_devices/robots/lekiwi_remote.py of the component ZeroMQ Socket Handler. The manipulation leads to missing authentication. The attack can only be initiated within the local network. The vendor was contacted early about this disclosure but did not respond in any way. |
| An issue was discovered in TitanHQ SpamTitan Email Security Gateway 8.00.x before 8.00.101 and 8.01.x before 8.01.14. The file quarantine.php within the SpamTitan interface allows unauthenticated users to trigger account-level actions using a crafted GET request. Notably, when a non-existent email address is provided as part of the email parameter, SpamTitan will automatically create a user record and associate quarantine settings with it - all without requiring authentication. |
| Delta Electronics DIAView has an authentication bypass vulnerability. |
| A potential missing authentication vulnerability was reported in some Lenovo Tablets that could allow an unauthorized user with physical access to modify Control Center settings if the device is locked when the "Allow Control Center access when locked" option is disabled. |